Bids are hereby invited for the following: Repairs to electricals at the pump room at Florida Fire Station water feature. Scope: - Supply, mount and connect star delta control box complete for a 3kw pump motor; - Supply, mount and connect star delta control box complete for a 30kw pump motor; - Make provision for electrical works; - Supply, install and connect three phase 100Amp circuit breaker (Din Rail); - Supply and deliver 60Amp three phase breakers (Din Rail Breakers). Department: FM. (Tender №98340833)

Country: South Africa
Language: EN
Number: 98340833
Publication date: 24-01-2024
Source:

Description

Full information on the tender is closed.
For further work with the site read the information below.

About us

Leading searching system of world tenders

  • Largest database of tenders and sources of procurement of the World
  • Free daily mailings according to Your settings
  • Winners information
  • Convenient display and downloading of information

Choose us

Getting Started

After site registration, this functions will be available to You

  • Subscription to free mailing list for your keyword phrases
  • Tenders announcements previews
  • Download summary information in Excel format
  • View information about tender winners, suppliers and customers

REGISTER

For using all functions of our site and view full information you need to register a commercial account

  • Selected period
  • Pay access in any of the possible ways

Get full access

Other tenders for this period

Quotations are hereby invited for the following: Transformer maintenance at SFF Milnerton. Scope of work: - Electrical contractor to do Major Service on our 12 x transformer. Transformer sizes are as follow: • 8 x 25kva = approximate litres = 168 litres; • 2 x 100 Kva = Approximate -322,7 litres; • 1 x 315Kva Approximate = 415 liters; • 1 x 300Kva = Approximate litres - 390 liters. Service include: • Test oil and provide oil report for each transformer, test must be done in accordance with transformer regulation. • Replace oil where oil do not meet the standard. • Refill Lower oil level with certified oil batch 3380532. • Check mechanical cooling system. • Check bushing of the transformer for cracks. • Replace gauge glass where necessary. • Replace breather oil where necessary. • Re-torque MV and LV bushing. • Apply Denso tape. • Clean transformer. • All label be done according to standard. Please confirm the contract number as two were published. Source: ONLINE TENDERS

Quotations are hereby invited for the following: Transformer maintenance at SFF Milnerton. Scope of work: - Electrical contractor to do Major Service on our 12 x transformer. Transformer sizes are as follow: • 8 x 25kva = approximate litres = 168 litres; • 2 x 100 Kva = Approximate -322,7 litres; • 1 x 315Kva Approximate = 415 liters; • 1 x 300Kva = Approximate litres - 390 liters. Service include: • Test oil and provide oil report for each transformer, test must be done in accordance with transformer regulation. • Replace oil where oil do not meet the standard. • Refill Lower oil level with certified oil batch 3380532. • Check mechanical cooling system. • Check bushing of the transformer for cracks. • Replace gauge glass where necessary. • Replace breather oil where necessary. • Re-torque MV and LV bushing. • Apply Denso tape. • Clean transformer. • All label be done according to standard. Please confirm the contract number as two were published. Source: ONLINE TENDERS

Bids are hereby invited for the following: Supply and deliver mobile toilets. Scope: - Supply and deliver single standard mobile toilet at Springfield, FM Depot; - Supply and deliver single VIP mobile toilet at Springfield, FM Depot. Department: FM. Source: ONLINE TENDERS

Bids are hereby invited for the following: Supply and deliver mobile toilets. Scope: - Supply and deliver single standard mobile toilet at Springfield, FM Depot; - Supply and deliver single VIP mobile toilet at Springfield, FM Depot. Department: FM. Source: ONLINE TENDERS

Bids are hereby invited for the following: Supply and delivery of 2 scrubbers. Specifications: - The scrubber must be compatible to DKL42/26-DK42/26; - Construction materials-Metal structure and PVC components; - Working in continuous - Admitted; - Flow regulation - UPNTO 25 L/min; - Vacuum regulation - Down to 200mbar ABS; - Capacity of glass tanks: 3.5L; - Power input: 130W; - Current consumption: 500MA; - Weight: 11kg, 24.3 lb; - Dimensions (W x H x D): 315 x 335 x 360 mm, 12.4 x 13.2 x 14.2 in. Source: ONLINE TENDERS

Bids are hereby invited for the following: Repairs to electricals at the pump room at Florida Fire Station water feature. Scope: - Supply, mount and connect star delta control box complete for a 3kw pump motor; - Supply, mount and connect star delta control box complete for a 30kw pump motor; - Make provision for electrical works; - Supply, install and connect three phase 100Amp circuit breaker (Din Rail); - Supply and deliver 60Amp three phase breakers (Din Rail Breakers). Department: FM. Source: ONLINE TENDERS